Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.912
Filtrar
1.
Bull World Health Organ ; 102(4): 255-264, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38562195

RESUMO

Objective: To assess the impact of an open fracture intervention bundle on clinical management and patient outcomes of adults in Malawi with open tibia fractures. Methods: We conducted a before-and-after implementation study in Malawi in 2021 and 2022 to assess the impact of an open fracture intervention bundle, including a national education course for clinical officers and management guidelines for open fractures. We recruited 287 patients with open tibia fractures. The primary outcome was a before-and-after comparison of the self-reported short musculoskeletal function assessment score, a measure of patient function. Secondary outcomes included clinical management; and clinician knowledge and implementation evaluation outcomes of 57 health-care providers attending the course. We also constructed multilevel regression models to investigate associations between clinical knowledge, patient function, and implementation evaluation before and after the intervention. Findings: The median patient function score at 1 year was 6.8 (interquartile range, IQR: 1.5 to 14.5) before intervention and 8.4 (IQR: 3.8 to 23.2) after intervention. Compared with baseline scores, we found clinicians' open fracture knowledge scores improved 1 year after the intervention was implemented (mean posterior difference: 1.6, 95% highest density interval: 0.9 to 2.4). However, we found no difference in most aspects of clinicians' open fracture management practice. Conclusion: Despite possible improvement in clinician knowledge and positive evaluation of the intervention implementation, our study showed that there was no overall improvement in clinical management, and weak evidence of worsening patient function 1 year after injury, after implementation of the open fracture intervention bundle.


Assuntos
Fraturas Expostas , Fraturas da Tíbia , Adulto , Humanos , Fraturas Expostas/cirurgia , Fraturas Expostas/complicações , Malaui , Tíbia , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/complicações , Resultado do Tratamento
2.
J Pediatr Orthop ; 44(5): e419-e425, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38595313

RESUMO

BACKGROUND: Congenital pseudarthrosis of the tibia (CPT) is a rare disease. CPT is often unilateral and occurs between the middle and distal third of the tibia. Concurrent involvement of the fibula is present in more than half of cases. histologic studies indicate the presence of fibrous hamartoma tissue and a sick periosteum, which leads to recalcitrant bone fracture and, eventually, pseudoarthrosis. Although there are various surgical techniques, we intend to compare the 2 methods of external fixation versus internal plating. METHODS: Demographic data were collected from 26 patients with frank pseudoarthrosis. After exclusion criteria, patients were compared in groups A (12 patients) and B (11 patients). Resection of hamartoma and sclerotic bone, intramedullary rodding and autologous bone, and periosteal grafting were performed for all patients. In group A, we used a ring external fixator for compression and rotational stability, but in group B, a locking plate was used for these purposes. RESULTS: Plating takes less time to use during surgery. In group A, the primary bony union was obtained in 67% of patients, while in group B, 82% of patients had a primary union. Meanwhile, the average time till the final union in group A was 6 months, while in group B, this time was 3.5 months. Positive union mass was obtained in 58% of the patients in group A and 82% of group B. In addition, plating prevented ankle valgus deformity in group B. CONCLUSIONS: Permanent intramedullary rodding is a surgical requirement for correction of deformity and refracture prevention, but additional stability can be achieved with the use of a ring external fixator or internal plate. Cross union and positive union mass are 2 important factors in the treatment of pseudoarthrosis; these results are achieved to a greater extent and in a shorter period of time using the plate. LEVEL OF EVIDENCE: level IV - case series.


Assuntos
Fixação Intramedular de Fraturas , Hamartoma , Pseudoartrose , Pseudoartrose/congênito , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Tíbia/patologia , Pseudoartrose/cirurgia , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/patologia , Fixação Intramedular de Fraturas/métodos , Fixadores Externos , Fíbula , Placas Ósseas , Estudos Retrospectivos , Hamartoma/patologia , Resultado do Tratamento
3.
Sci Rep ; 14(1): 7982, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38575734

RESUMO

How to deal with large tibial bone defects is still controversial. The purpose of this research was to compare the semi-focal bone transport (SFBT) technique with traditional bone transport (TBT) technique for treating such patients. Sixty-two patients were included and retrospectively analyzed. In all cases, after radical debridement large tibial bone defects remained. Patients were treated by the SFBT or TBT technique. The distraction, consolidation duration and complications were recorded by the patients' medical files. Based on the Association for the Study and Application of Methods of Ilizarov (ASAMI) standard, the bone and functional results were evaluated. The mean bone defect size was 7.7 ± 1.6 cm and 7.5 ± 2.1 cm for SFBT and TBT patients. The mean external fixation index (EFI) was 1.51 ± 0.14 months/cm and 1.89 ± 0.25 months/cm for SFBT and TBT patients (p < 0.05), respectively. With respect to bone and function results, there was no significant differences between the two groups (p > 0.05). The mean number of complications per patient was 1.1 ± 0.6 and 1.6 ± 0.7 for SFBT and TBT patients (p < 0.05). Compared to the traditional bone transport technique, patients using the semi-focal bone transport technique achieved better clinical effects, including shorter EFI and less complications. Therefore, the SFBT technique could be a new option for patients with large tibial bone defects.


Assuntos
Técnica de Ilizarov , Osteogênese por Distração , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Estudos Retrospectivos , Tíbia , Osteogênese por Distração/métodos , Resultado do Tratamento
4.
Medicine (Baltimore) ; 103(14): e37647, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579094

RESUMO

BACKGROUND: Blocking screw technique has been widely applied in the treatment of long shaft fractures. However, the evidence with regard to whether intramedullary nail combined with blocking screw technique has better clinical efficacy over other is not clear. The aim of the study was to explore the clinical efficacy and complications of intramedullary nail combined with blocking screw technique in the treatment of femoral or tibial shaft fractures. METHODS: The PuMed, Embase, OVID, Cochrane library, Web of Science, Wanfang, CNKI and Weipu data were searched for studies of intramedullary nail combined with blocking screw in treatment of femoral or tibial shaft fracture published up to Aug 31 2023. Methodological quality of the trials was assessed, relevant data were extracted, and RevMan 5.3 and Stata 15.0 software were used to perform the meta-analysis of parameters related to the consequences. RESULT: Twenty articles were included, including 1267 patients. Meta-analysis results showed that compared with the non-blocking screw group, the blocking screw group had longer operation time (WMD = 13.24; 95% CI = 5.68-20.79, P = .0006) and more intraoperative fluoroscopy times (WMD = 57.62; 95% CI = 25.82-89.42, P = .0002). However, the postoperative therapeutic response rate was higher (OR = 5.60; 95% CI = 2.10-14.93, P = .0006), postoperative ankle joint function was better (OR = 3.48; 95% CI = 1.20-10.13, P = .02), and fracture healing rate was higher (OR = 3.56; 95% CI = 1.43-8.89, P = .006), fracture healing time was shorter (WMD = -3.59; 95% CI = -4.96 to -2.22, P < .00001), intraoperative blood loss was less (WMD = -54.80; 95% CI = -88.77 to -20.83, P = .002), hospitalization time was shorter (WMD = -1.66; 95% CI = -2.08 to -1.24, P < .00001), and complications were less (OR = 0.38; 95% CI = 0.16-0.89, P = .01). There was no statistical significance in the range of motion of knee joint between the 2 groups (WMD = 10.04; 95% CI = -1.51 to 21.59, P = .09). CONCLUSIONS: Current evidence shows that intramedullary nail combined with blocking screw technique in the treatment of lower limb long bone fracture has the advantages of good clinical efficacy, high fracture healing rate, short fracture healing time, good joint function, less complications and so on, which is worthy of clinical recommendation.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Parafusos Ósseos , Resultado do Tratamento , Fraturas da Tíbia/cirurgia , Extremidade Inferior , Pinos Ortopédicos
5.
BMC Surg ; 24(1): 103, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600472

RESUMO

BACKGROUND: There is no effective consensus on the choice of internal fixation method for the Masquelet technique in the treatment of large segmental bone defects of the distal tibia. Thus, the study aimed to investigate the outcomes of the Masquelet technique combined with double plate fixation in the treatment of large segmental bone defects. METHODS: This was a retrospective study involving 21 patients with large segmental bone defects of the distal tibia who were treated between June 2017 and June 2020. The length of bone defect ranged from 6.0 cm to 11 cm (mean, 8.19 cm). In the first stage of treatment, following complete debridement, a cement spacer was placed to induce membrane formation. In the second stage, double plate fixation and autologous cancellous bone grafting were employed for bone reconstruction. Each patient's full weight-bearing time, bone healing time, and Iowa ankle score were recorded, and the occurrence of any complications was noted. RESULTS: All patients were followed up for 16 to 26 months (mean, 19.48 months). The group mean full weight-bearing time and bone healing time after bone grafting were 2.41 (± 0.37) months and 6.29 (± 0.66) months, respectively. During the treatment, one patient had a wound infection on the medial side of the leg, so the medial plate was removed. The wound completely healed after debridement without any recurrence. After extraction of iliac bone for grafting, one patient had a severe iliac bone defect, which was managed by filling the gap with a cement spacer. Most patients reported mild pain in the left bone extraction area after surgery. The postoperative Iowa ankle score range was 84-94 (P < 0.05). In this cohort, 15 cases were rated as "excellent", and 6 cases as "good" on the Iowa ankle scoring system. CONCLUSION: The Masquelet technique combined with double plate fixation is a safe and effective method for the treatment of large segmental bone defects of the distal tibia.


Assuntos
Procedimentos de Cirurgia Plástica , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Estudos Retrospectivos , Extremidade Inferior/cirurgia , Fixação Interna de Fraturas , Transplante Ósseo/métodos , Resultado do Tratamento , Fraturas da Tíbia/cirurgia
6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 426-431, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632061

RESUMO

Objective: To explore the effectiveness of using antibiotic bone cement-coated plates internal fixation technology as a primary treatment for Gustilo type ⅢB tibiofibular open fractures. Methods: The clinical data of 24 patients with Gustilo type ⅢB tibiofibular open fractures who were admitted between January 2018 and December 2021 and met the selection criteria was retrospectively analyzed. Among them, there were 18 males and 6 females, aged from 25 to 65 years with an average age of 45.8 years. There were 3 cases of proximal tibial fracture, 6 cases of middle tibial fracture, 15 cases of distal tibial fracture, and 21 cases of fibular fracture. The time from injury to emergency surgery ranged from 3 to 12 hours, with an average of 5.3 hours. All patients had soft tissue defects ranging from 10 cm×5 cm to 32 cm×15 cm. The time from injury to skin flap transplantation for wound coverage ranged from 1 to 7 days, with an average of 4.1 days, and the size of skin flap ranged from 10 cm×5 cm to 33 cm×15 cm. Ten patients had bone defects with length of 2-12 cm (mean, 7.1 cm). After emergency debridement, the tibial fracture end was fixed with antibiotic bone cement-coated plates, and the bone defect area was filled with antibiotic bone cement. Within 7 days, the wound was covered with a free flap, and the bone cement was replaced while performing definitive internal fixation of the fracture. In 10 patients with bone defect, all the bone cement was removed and the bone defect area was grafted after 7-32 weeks (mean, 11.8 weeks). The flap survival, wound healing of the affected limb, complications, and bone healing were observed after operation, and the quality of life was evaluated according to the short-form 36 health survey scale (SF-36 scale) [including physical component summary (PCS) and mental component summary (MCS) scores] at 1 month, 6 months after operation, and at last follow-up. Results: All 24 patients were followed up 14-38 months (mean, 21.6 months). All the affected limbs were successfully salvaged and all the transplanted flaps survived. One case had scar hyperplasia in the flap donor site, and 1 case had hypoesthesia (grade S3) of the skin around the scar. There were 2 cases of infection in the recipient area of the leg, one of which was superficial infection after primary flap transplantation and healed after debridement, and the other was sinus formation after secondary bone grafting and was debrided again 3 months later and treated with Ilizarov osteotomy, and healed 8 months later. The bone healing time of the remaining 23 patients ranged from 4 to 9 months, with an average of 6.1 months. The scores of PCS were 44.4±6.5, 68.3±8.3, 80.4±6.9, and the scores of MCS were 59.2±8.2, 79.5±7.8, 90.0±6.6 at 1 month, 6 months after operation, and at last follow-up, respectively. The differences were significant between different time points ( P<0.05). Conclusion: Antibiotic bone cement-coated plates internal fixation can be used in the primary treatment of Gustilo type ⅢB tibiofibular open fractures, and has the advantages of reduce the risk of infection in fracture fixation, reducing complications, and accelerating the functional recovery of patients.


Assuntos
Fraturas Expostas , Lesões dos Tecidos Moles , Fraturas da Tíbia , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Tíbia/cirurgia , Cimentos Ósseos , Fraturas Expostas/cirurgia , Antibacterianos , Cicatriz/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Fraturas da Tíbia/cirurgia , Transplante de Pele , Fixação Interna de Fraturas/efeitos adversos , Lesões dos Tecidos Moles/cirurgia
7.
J Pak Med Assoc ; 74(3): 440-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591274

RESUMO

Objective: To determine the combined column tibial plateau fracture treated with a hybrid external fixator in terms of knee functionality, union outcome and complications. METHODS: The quasi-experimental study was conducted at the Department of Orthopaedic Surgery, Mayo Hospital, Lahore, Pakistan, from July 5, 2019, to December 31, 2021, and comprised patients of either gender aged 20-50 years who presented with 2-column or 3-column fractures of proximal tibia classified according to the 3-column classification system after being diagnosed using radiographs and three-dimensional computed tomography scan. Knee function, union and complications, like neural, vascular, infection, delayed union, nonunion, malunion and implant failure, were evaluated. The Knee Society Score was used to assess knee function, and modified Rasmussen score for the union, while complications were assessed clinically on the 2nd, 6th, 12th, 16th, 24th, 36th weeks and one year post-operatively. Data was analysed using SPSS 26. RESULTS: Of the 113 patients, 91(80.53%) were males and 22(19.47%) were females. The overall mean age was 35.56±9.00 years. From the 12th week to the 24th week 45(39.83%) patients had good and 59(52.21%) patients had excellent functional outcomes. Union outcome in the 16th and 24th week was good in 57(50.44%) patients and excellent in 47(41.59%) patients. No neurovascular injury was observed. Superficial pin tract infection was observed in 21(18.6%) cases that healed with wound debridement and antibiotics. No delayed union, malunion and implant failure was observed. CONCLUSIONS: Good to excellent functional and union outcomes with minimum complications were observed with the hybrid external fixator.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Masculino , Feminino , Humanos , Adulto , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
8.
J Orthop Traumatol ; 25(1): 21, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637406

RESUMO

BACKGROUND: Treating tibial non-unions efficiently presents a challenge for orthopaedic trauma surgeons. The established gold standard involves implanting autologous bone graft with adequate fixation, but the addition of biologicals according to the so-called diamond concept has become increasingly popular in the treatment of non-unions. Previous studies have indicated that polytherapy, which involves implanting mesenchymal stem cells, bioactive factors and osteoconductive scaffolds, can improve bone healing. This study aims to evaluate the efficacy of polytherapy compared with monotherapy in treating tibial non-unions of varying severity. MATERIALS AND METHODS: Data from consecutive tibial non-unions treated between November 2014 and July 2023 were retrospectively analysed. The Non Union Scoring System (NUSS) score before non-union surgery, and the Radiographic Union Score for Tibial fractures (RUST), scored at 1, 3, 6, 9, 12 and 18 months post-surgery, were recorded. Initially, a comparison was made between the polytherapy and monotherapy groups. Subsequently, patients receiving additional surgical non-union treatment were documented, and the frequency of these treatments was tallied for a subsequent per-treatment analysis. RESULTS: A total of 34 patients were included and divided into a polytherapy group (n = 15) and a monotherapy group (n = 19). The polytherapy group demonstrated a higher NUSS score (44 (39, 52) versus 32 (29, 43), P = 0.019, z = -2.347) and a tendency towards a higher success rate (93% versus 68%, P = 0.104) compared with the monotherapy group. For the per-treatment analysis, 44 treatments were divided into the polytherapy per-treatment group (n = 20) and the monotherapy per-treatment group (n = 24). The polytherapy per-treatment group exhibited a higher NUSS score (48 (43, 60) versus 38 (30, 50), P = 0.030, z = -2.173) and a higher success rate (95% versus 58%, P = 0.006) than the monotherapy per-treatment group. Within the monotherapy per-treatment group, the NUSS score displayed excellent predictive performance (AUC = 0.9143). Setting the threshold value at 48, the sensitivity and specificity were 100.0% and 70.0%, respectively. CONCLUSIONS: Polytherapy is more effective than monotherapy for severe tibial non-unions, offering a higher success ratio. The NUSS score supports decision-making in treating tibial non-unions. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas não Consolidadas , Fraturas da Tíbia , Humanos , Estudos Retrospectivos , Fraturas não Consolidadas/terapia , Consolidação da Fratura , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Transplante Ósseo , Resultado do Tratamento
9.
Int Wound J ; 21(3): e14715, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38494179

RESUMO

To systematically explore the effects of minimally invasive plate osteosynthesis (MIPO) versus intramedullary nail (IMN) on wound infection and wound healing in patients with distal tibia fractures. A computerised search of PubMed, Web of Science, Cochrane Library, Embase, Wanfang, China Biomedical Literature Database (CBM) and China National Knowledge Infrastructure databases was performed, from their inception to October 2023, to identify relevant studies on the application of MIPO and IMN in patients with distal tibial fractures. The quality of the included literature was evaluated by two researchers based on inclusion and exclusion criteria, and basic information of the literature was collected, with wound infection, postoperative complications and wound healing time as the main indicators for analysis. Stata 17.0 software was applied for analysis. Overall, 23 papers and 2099 patients were included, including 1026 patients in the MIPO group and 1073 patients in the IMN group. The results revealed, when compared with IMN treatment, patients with distal tibia fractures who underwent MIPO treatment had a lower incidence of postoperative complications (OR = 0.33, 95% CI: 0.25-0.42, p < 0.001) and a shorter wound healing time (SMD = -1.00, 95% CI: -1.51 to -0.49, p < 0.001), but the incidence of postoperative wound infection was higher (OR = 2.01, 95% CI: 1.35-3.01, p = 0.001). Both MIPO and IMN are excellent treatments for distal tibia fractures. MIPO is effective in reducing the incidence of complications as well as shortening the time of wound healing time but increases the risk of wound infection. In clinical practice, surgeons can make individual choices based on the patient's wishes and proficiency in both techniques.


Assuntos
Fraturas do Tornozelo , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/efeitos adversos , Fraturas da Tíbia/cirurgia , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento
10.
J Long Term Eff Med Implants ; 34(3): 23-26, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505890

RESUMO

Schatzker III tibial plateau fractures (TPF) reduction and stabilization still represents a challenging procedure. We present an alternative, percutaneous surgical technique. With an antero-medial transverse incision at the level of the tibial metaphysis, under fluoroscopic control, an osteotome is advanced from medial to lateral, under the depressed fragments, reducing the articular surface of the lateral TP anatomically, without creating a significant void and preserving the lateral wall. Final fixation is achieved with screws placed from lateral to medial in a percutaneous fashion, parallel to the articular surface to hold fragments in a rafting way. Open surgical techniques hide many pitfalls and several new reduction options have been described; some simple but invasive, using bone tamps and bone graft that increase surgical trauma; others reliable and safe, but demanding and difficult to reproduce, needing good arthroscopic skills or special and expensive instrumentation, therefore not always available in the operating theater. We prefer a medially based percutaneous metaphyseal bone access using two simple flat low profile instruments such as osteotomes, that preserve bone and vascularization during the reduction maneuvers, minimizing the above-mentioned risks, for the treatment of Schatzker type III TPF.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Fixação Interna de Fraturas , Fluoroscopia , Fraturas da Tíbia/cirurgia , Transplante Ósseo
11.
J Orthop Surg Res ; 19(1): 201, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532441

RESUMO

BACKGROUND: This study investigated the biomechanical properties of a new plate used for the treatment of posterolateral tibial plateau fractures using finite element analysis. METHODS: The study groups were as follows: group PM, model of the new plate with posteromedial tibial plateau fracture; group PL, model of the new plate with posterolateral tibial plateau fracture; and group PC, model of the new plate with posterior tibial plateau fracture. We used two loading modes: uniform loading on the entire plateau, and loading on the posterior plateau. Data such as the displacement of the fracture and distribution of stress on the new plate and screws were recorded and analyzed. RESULTS: When the whole plateau was loaded, the displacement of fractures in groups PM, PL, and PC were 0.273, 0.114, and 0.265 mm, respectively. The maximum stresses on the plates in groups PM, PL, and PC were 118.131 MPa, 44.191 MPa, and 115.433 MPa. The maximum stresses on the screws in Groups PM, PL, and PC were 166.731, 80.330, and 164.439 MPa, respectively. When the posterior tibial plateau was loaded, the displacement of the fractures in groups PM, PL, and PC was 0.410, 0.213, and 0.390 mm, respectively. The maximum stresses on the plates in groups PM, PL, and PC were 194.012 MPa, 72.806 MPa, and 185.535 MPa. The maximum stresses on the screws in Groups PM, PL, and PC were 278.265, 114.839, and 266.396 MPa, respectively. CONCLUSION: The results of this study revealed that titanium plates have good fixation effects in all groups; therefore, the use of the new plate for posterolateral tibial plateau fractures appears to be safe and valid.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Análise de Elementos Finitos , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Tíbia , Placas Ósseas , Fenômenos Biomecânicos
12.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 267-271, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500417

RESUMO

Objective: To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods: A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results: The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores ( P<0.05). Conclusion: Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.


Assuntos
Lesões do Ligamento Cruzado Anterior , Fratura Avulsão , Ligamento Cruzado Posterior , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Ligamento Cruzado Posterior/cirurgia , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Anterior/cirurgia , Fratura Avulsão/cirurgia , Estudos Retrospectivos , Lesões do Ligamento Cruzado Anterior/cirurgia , Resultado do Tratamento , Artroscopia/métodos , Técnicas de Sutura , Articulação do Joelho/cirurgia , Fraturas da Tíbia/cirurgia
13.
Med Eng Phys ; 125: 104122, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508793

RESUMO

The embracing fixator is one of the widely used internal fixation implants for bone fracture treatment. However, the stress shielding effect, a stress imbalance between the implant and bone caused by the mismatch in mechanical properties between them, is a significant and critical issue that may lead to treatment failure. Thus, it is of great importance to design the implant with an appropriate stiffness which can mitigate the stress shielding effect and provide the most favorable mechanical environment for bone healing and remodeling. To this end, a time-dependent topology optimization algorithm considering bone remodeling is proposed to optimize an embracing fixator used in the tibia fracture treatment. The change of callus density over time is simulated based on a bone remodeling model, and the callus density after a period of bone remodeling is selected to be the design objective to maximize. The design constraints include volume and the compliance of the whole fixation system. Meanwhile, the influence of the constraints on the regularity of material distribution of the optimized result is also studied. Besides, to test the effectiveness of the consideration of the bone remodeling in the embracing fixator design, a topology optimization concerning the minimization of the compliance of the entire system is also performed to make a comparison. Finally, the safety performance of optimized results considering bone remodeling is also verified by static analysis.


Assuntos
Próteses e Implantes , Fraturas da Tíbia , Humanos , Remodelação Óssea , Calo Ósseo , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Consolidação da Fratura
14.
Medicine (Baltimore) ; 103(11): e37417, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489726

RESUMO

Elastic stable intramedullary nailing (ESIN) has been shown to be an effective form of surgical management for lower-extremity diametaphyseal fractures in pediatric patients, but studies are limited because ESIN treatment for these fractures is relatively uncommon. We sought to determine whether ESIN can be used effectively in the most distal or proximal short-segment forms of these fractures. We queried the electronic medical record system at Johns Hopkins Hospital using Current Procedural Terminology codes for femur and tibia fractures treated with ESIN in patients under 18 years old between January 2015 and October 2022. Preoperative and postoperative radiographs were subsequently reviewed to identify patients with a proximal or distal third femoral or tibial shaft fracture treated with ESIN and to define criteria for short-segment diametaphyseal fractures. We used Beaty radiological criteria to evaluate radiographic outcomes and Flynn titanium elastic nails (TENs) outcome scale to assess clinical recovery after radiographic evidence of union. There were 43 children who met the inclusion criteria. Among them, 10 patients had short-segment diametaphyseal fractures. There were 22 (51.2%) who sustained femur fractures and 21 (48.8%) who sustained tibia fractures. Using Beaty radiologic criteria, ESIN was associated with more satisfactory outcomes in patients with distal or proximal third shaft fractures (32/33) than in patients with short-segment diametaphyseal fractures (7/10) (P = .03). Using the TENs outcome scale, 21 (63.4%) patients with distal or proximal third shaft fractures had excellent results, 11 (33.3%) had satisfactory results, and 1 (3%) had a poor result. Among patients with short-segment diametaphyseal fractures, 4 (40%) had excellent results, 5 (50%) had satisfactory results, and 1 (10%) had a poor result. There were no differences in TENs outcomes between the groups (P = .24). Patients with short-segment lower-extremity diametaphyseal fractures treated with ESIN had worse radiographic outcomes but did no worse clinically than patients with distal or proximal third shaft fractures. Consequently, ESIN should be considered a safe and effective surgical management option for pediatric patients with even the most distal or proximal forms of these fractures.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Criança , Adolescente , Fixação Intramedular de Fraturas/métodos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Radiografia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Extremidade Inferior , Resultado do Tratamento , Pinos Ortopédicos , Consolidação da Fratura , Estudos Retrospectivos
15.
Zhongguo Gu Shang ; 37(3): 300-5, 2024 Mar 25.
Artigo em Chinês | MEDLINE | ID: mdl-38515419

RESUMO

OBJECTIVE: To explore clinical efficacy of autologous bone grafts and bone substitute for the treatment of tibial plateau fractures by Meta analysis. METHODS: Controlled clinical studies on autogenous bone transplantation and bone substitutes in treating tibial plateau fractures published on PubMed,Web of Science,CNKI,Wanfang and other databases from January 2005 to August 2022 were searched by computer. Literature screening and data extraction were performed according to randomized controlled trial(RCT),and the quality of RCT were evaluated by using intervention meta-analysis criteria in Cochrane manual. Meta-analysis of joint depression,secondary collapse rate of articular surface,blood loss,operative time and infection rate between two methods were performed by Rev Man 5.3 software. RESULTS: Seven RCT studies (424 patients) were included,296 patients in bone replacement group and 128 patients in autograft group. Operative time [MD=-16.79,95%CI(-25.72,-7.85),P=0.000 2] and blood loss[MD=-70.49,95%CI(-79.34,-61.65),P<0.000 01] between two groups had statistically differences,while joint depression[MD=-0.17,95%CI(-0.91,0.58),P=0.66],secondary collapse rate of joint surface[RR=-0.74, 95%CI(0.35,1.57),P=0.43],infection rate [RR=1.21,95%CI(0.31,4.70),P=0.78] between two groups had no differences. CONCLUSION: The effects of bone substitute and autograft for the treatment of tibial plateau fracture have similar effects in terms of joint depression,secondary articular surface collapse rate and infection rate. However,compared with autologous bone transplantation,bone replacement could reduce blood loss and shorten operation time.


Assuntos
Substitutos Ósseos , Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Substitutos Ósseos/uso terapêutico , Transplante Ósseo/métodos , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Fixação Interna de Fraturas/métodos
16.
J Biomech Eng ; 146(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426592

RESUMO

In this research, an experimental biomechanics construct was developed to reveal the mechanics of distal tibial fracture by submitting synthetic tibiae to cyclic loading, resulting in a combined stress state due to axial compression and bending loads. The synthetic tibia was fixed at the knee but allowed to rotate in the coronal and sagittal planes at the ankle. The first three loading regimes lasted for 4000 cycles/each, and the final until ultimate failure. After 12k±80 cycles, the observed failure patterns closely resembled distal tibial fractures. The collected data during cyclic loading were fitted into a phenomenological model to deduce the time-dependent response of the synthetic tibiae. Images were also collected and analyzed using digital image correlation to deduce the full-field state of strain. The latter revealed that longitudinal strain contours extended in the proximal-distal direction. The transverse strain contours exemplified a medial-to-lateral distribution, attributed to the combined contributions of the Poisson's effect and the flexural deformation from axial and bending components of the applied load, respectively. The experimental construct, full-field characterization, and data analysis approaches can be extended to elucidate the effect of different fixation devices on the overall mechanical behavior of the bone and validate computational models in future research.


Assuntos
Tíbia , Fraturas da Tíbia , Humanos , Estudos de Viabilidade , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Articulação do Joelho
17.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1308-1316, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504506

RESUMO

PURPOSE: The aim of this study was to analyse the functional outcome and the conversion rate to total knee arthroplasty (TKA) after surgically treated tibial plateau fractures (TPF). METHODS: All patients undergoing surgical treatment of TPF at a single institution between January 2003 and December 2019 were retrospectively reviewed. The Knee injury and Osteoarthritis Outcome Score (KOOS) and Tegner activity scale (TAS) were collected. The conversion rate to TKA was examined 2, 5, 7 and 10 years after surgical treatment of TPF. RESULTS: Ninety-four patients, with a mean follow-up of 110.6 months (±60.0), were included in the functional outcome assessment. Mean KOOS scores were 75.4 for symptoms, 80.6 for pain, 84.3 for activities of daily living (ADL), 59.5 for sports and 61.3 for QOL. All subscales were significantly lower on the injured side compared with the contralateral leg. Lower KOOS was observed in patients with hardware removal and Schatzker type 5 and 6 injuries. Median TAS was postinjury (4) significantly lower than preinjury (5) (p < 0.001). The conversion rate to TKA was 6.3%, 10.9%, 11.7% and 12.2% after 2,5,7 and 10 years of follow-up, respectively. Patients undergoing TKA were older than patients with no conversion to TKA (2 years follow-up 53.8 vs. 64.5 years, p = 0.026). CONCLUSION: TPFs decrease the function of the knee when compared with the contralateral side and to the preoperative condition. Bicondylar fractures are associated with worse functional outcomes. A conversion rate to TKA of 12.2% was found at 10 years follow-up. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Humanos , Feminino , Masculino , Fraturas da Tíbia/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Atividades Cotidianas , Adulto , Resultado do Tratamento , Recuperação de Função Fisiológica , Fraturas do Planalto Tibial
19.
Med Sci Monit ; 30: e944136, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549240

RESUMO

BACKGROUND Tibial fractures, common in adults, are often treated with external or internal fixation methods. While effective, external fixation (EF) can lead to sexual dysfunction (SD), especially in young patients. This study aimed to assess SD in women undergoing EF versus internal fixation for tibial fractures. MATERIAL AND METHODS Sexual function and frequency of monthly sexual intercourse (SI) were evaluated using the Female Sexual Function Index (FSFI) before surgery, with the fixator, after at least 6 months following fixator removal in EF group, and after achieving bone union for at least 3 months in the IF group. RESULTS The EF group consisted of 107 (mean age 28.5 years; 19-40 years) and IF group consisted of 106 patients (mean age 32.1 years; 18-40 years). The duration of EF was an average of 4.7 months (range, 2.5-13 months). FSFI scores were significantly lower in the EF group compared to the IF group (9.33 versus 27.3, P<0.001). Also, there was no significant difference between the FSFI scores before EF and after EF was removed (34.22 versus 33.8, P=0.413). FSFI sub-group scores such as desire, arousal, lubrication, and orgasm were significantly lower in the EF group (P<0.001). The monthly average frequency of SI before surgery and after the removal of EF was 10.2 and 9.1, respectively, while this frequency was 2.56 when EF was present (P<0.001). CONCLUSIONS The quality and frequency of SI in women significantly deteriorate and decrease during the period of extremity fixation following tibial diaphyseal fractures treated with EF, but return to normal after removal.


Assuntos
Disfunções Sexuais Fisiológicas , Fraturas da Tíbia , Adulto , Humanos , Feminino , Estudos Retrospectivos , Fixadores Externos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fixação de Fratura/métodos , Resultado do Tratamento
20.
Orthopadie (Heidelb) ; 53(4): 275-283, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38528206

RESUMO

Complications in the early postoperative period following the implantation of a unicondylar knee arthroplasty (UKA) are both rare and rarely described in the literature. Often, only small case series or individual case reports are available. In this article, the most common complications of periprosthetic infection, periprosthetic tibial fracture, inlay dislocation and intra-articular cement residue in (loose bone cement body) are described and recommendations for conservative and surgical treatment are presented, including case examples. Ideally, surgical errors or an infection should be recognized at an early stage and revised as soon as possible.


Assuntos
Artroplastia do Joelho , Fraturas Periprotéticas , Fraturas da Tíbia , Humanos , Artroplastia do Joelho/efeitos adversos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Fraturas Periprotéticas/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...